DS2172 Simplified Receiver Operation

Abstract

DS2172 Bit Error Rate Tester (BERT) simplified receiver operation during repetitive pattern mode.

Operation During Repetitive Pattern Mode

Figure 1. PATTERN RECEIVE REGISTERS

PATTERN RECEIVE REGISTERS

Notes:

  1. All receive circuitry disabled when RDIS = 1.
  2. Clocks not shown for clarity.

6 OUT OF 64 BITS IN ERROR
ALL A & B AND PCR 2-0

Figure 2.

32 CONSECUTIVE MATCHES
AT A&B