Home
Search
left arrow Back to Home
Magnifying Glass Icon close icon

You searched for “ltc4162”

Filters

Filter Icon

Filters

Expand or Collapse Filter Icon
Expand or Collapse Filter Icon
Product Categories
  • A/D Converters (ADC) 3
  • Analog Functions 1
  • Clock and Timing 1
  • Interface and Isolation 2
    • Digital Isolation Technology 1
    • USB Products 1
  • Power Management 65
Expand or Collapse Filter Icon
Resources
  • Technical Documentation 2
Expand or Collapse Filter Icon
Industry Solutions
  • Automotive Solutions 1
  • Consumer Technology Solutions 2
  • Data Center Solutions 1
  • Energy Solutions 1
  • Healthcare Solutions 1
Expand or Collapse Filter Icon
Tools and Models
Expand or Collapse Filter Icon
Technology Solutions
  • Power Solutions 1
Expand or Collapse Filter Icon
Site Section
  • 2
Expand or Collapse Filter Icon
Result Type
  • 6
  • 1,317
  • 432
Expand or Collapse Filter Icon
Groups, Forums & Libraries
  • 131
  • 3
  • 1
  • 1
  • 1
  • 1
  • 2
  • 1
Expand or Collapse Filter Icon
Author
  • 454
  • 20
  • 10
  • 10
  • 8
  • 39
  • 16
  • 8
Expand or Collapse Filter Icon
Tag
  • 187
  • 180
  • 145
  • 126
  • 101
  • 95
  • 70
  • 53
Analog Devices Inc. logo Results on Analog.com
2
engineer-zone-play-icon Results on EngineerZone
1,755

Results on Analog.com

2
Relevance
Relevance
Oldest First
Newest First

Sort by

  • Product_categories.lvl0:Interface and Isolation
Clear All Filters Icon
External Link Icon Right Arrow Icon External Link Icon External Link Icon Tag pst-icon
  1. Industrial Battery Chargers Overview
    Solutions Bulletin & Brochure
    Analog Devices offers highly reliable and efficient integrated wired and wireless multi-chemistry charger controller solutions, which are suitable for a broad range of applications, including industrial automation, medical, logistics and retail, backup systems, instrumentation, and energy harvesting.

    PDF

    Industrial Battery Chargers Overview

    2.09 M

  2. Wireless Power Transmission
    Technical Articles
    Jun 1, 2019

    Frederik Dostal

    Wireless transmission of power has numerous advantages. For example, it makes fault-prone plug contacts redundant.
  • <<
  • <
  • 1
  • >
  • >>

Results on EngineerZone

1,755
    Clear All Filters Icon
    1. LTC4162-L minimum input voltage

      Forum Thread
      Answered
      Power Management
      21 September, 2022
      What is the minimum input voltage per battery cell in order to allow charging? I am designing a circuit which requires a boost converter before the LTC4162-L. The LTC4162-L will charge a 4-cell Li-ion battery pack in my design. I am testing with the DC2038A-A …
      LTC4162-LSwitching Battery ChargersLTC4162-LADbattery charger icinput voltageltc4162Choose a category

    2. LTC4162 SMBALERT output

      Forum Thread
      Answered
      Power Management
      12 August, 2022
      Hello, I build my own board with a LTC4162-S. I'm trying to configure the telemetry and SMBALERT output pin but it didn't work as expected, or I miss something in the datasheet. CONFIG_BITS_REG(@) = (by configuration, and verified by re-reading it) : telemetry_speed = 1 and …
      Switching Battery ChargersDatasheet/Specsbattery charger icltc4162LTC4162-S

    3. Force LTC4162 to charge

      Forum Thread
      Answered
      Power Management
      06 July, 2022
      I'm using an LTC4162 to charge an RRC2040 battery. It works correctly under standard usage. The battery has a "shipping mode" it can be configured into, after which it requires a pulse of power for several seconds from the charger to wake up again. The charger however doesn't …
      power managementsoftwareltc4162LTC4162EUFD

    4. LTC4162 charger state register() remains always zero

      Forum Thread
      Answered
      Power Management
      09 March, 2022
      Hi, I am using LTC4162IUFD-SADM for our charging design.Not able to see any changes on register even if charging and discharging working fine. Is there a way to enable the register ?Register dump is as below. Thanks for your help in advance. Best Regards,Divyesh Patel
      chargerltc4162battery managementbattery chargerCharging IC

    5. Issues with symmetric charger design LTC4162

      Forum Thread
      Answered
      Power Management
      04 March, 2022
      … with a scope: This plot was made with the PCB2 not connected to measure the battery detection signal. The lines named with 4162C is the LTC4162EUFD-L41#PBF chip (my design) and the line named with 4162A is the LTC4162EUFD-LAD#PBF chip programmed to icharge_jeita=0.6 (dev …
      Symmetric designCharger designBattery detectionltc4162

    6. Question about register setting values of LTC4162-L41/LAD and difference between LTC4162-L41 and LTC4162-LAD.

      Forum Thread
      Answered
      Power Management
      21 February, 2022
      … between LTC4162-L41,LTC4162-LAD and LTC4162-LADM ? I can find below things only, so please let me know about differences at schematic design. 1. LTC4162-LAD and LTC4162-LADM : Initial MPPT value 2. LTC4162-L41 and LTC4162-LAD/LTC4162-LADM: LTC4162-L41 is a fixed voltage and LTC4162-LAD …
      LTC4162-LADMLTC4162-LADC_OVER_X_Thresholdltc4162LTC4162-L41

    7. LTC4162L I2C port hangs. How can I reset it?

      Forum Thread
      Answered
      Power Management
      26 January, 2022
      Hello!I use ic ltc4162L in my project. There were situations when ic's i2c telemetry hung deadly. And the only way to restore an ic from this state was to reconnect an external power path (to Vin node) completely.Question: This ic doesn't have external reset pin. How …
      i2cltc4162

    8. LTC4162-SAD vcharge_dac stuck at 0 not charging

      Forum Thread
      Answered
      Battery Management System
      30 July, 2021
      I'm using a LTC4162-SAD to charge two 12V lead acid batteries in series. I've set the charger to charge at 26.3V, 3A max input and 16A, max output current. The batteries currently sit at 23.8V with 28V input voltage. The charger is in a cc …
      ltc4162battery chargerLead-acid battery

    9. Q. LTC4162-L, Please check the output waveform.

      Forum Thread
      Answered
      Power Management
      25 March, 2021
      Hello. It doesn't charge. The output waveform is strange. (BATSENS+) It is almost the same as the datasheet circuit or EVB circuit, but I don't know why. The customer tested it by setting the load to CV 26V instead of the battery. The values of L1 and C90 …
      LTC4162-LSwitching Battery Chargersbattery charger icltc4162DC2038Abattery charger

    10. Q. LTC4162-L, The BATSENS+ output is slightly weird.

      Forum Thread
      Answered
      Power Management
      23 March, 2021
      Hello. The BATSENS+ output is slightly weird. It is almost the same as the datasheet circuit or EVB circuit, but I don't know why. The customer tested it by setting the load to CV 26V instead of the battery. The values of L1 and C90 have already been changed …
      LTC4162-LSwitching Battery Chargersbattery charger icltc4162DC2038A

    • <<
    • <
    • 1
    • 2
    • 3
    • 4
    • 5
    • 6
    • 7
    • >
    • >>
  • Who We Are
  • Careers
  • Newsroom
  • What We Do (Signals+)
  • Investor Relations
  • Quality & Reliability
  • Sales and Distribution
  • What's New on Analog.com
  • Contact Us
  • Support
  • EngineerZone
  • Resources
  • Wiki
  • Analog Dialogue
  • ADI Developer Portal
  • Legal and Risk
  • Accessibility
  • Privacy Policy
  • Privacy Settings
  • Cookie Settings
  • EZ
  • Linkedin
  • Instagram
  • Youtube
  • Facebook
  • Twitter