parts 32 Sort parts sorting button | Drag And Drop Hide Opens a dialog box. Description Sort Description sorting button | Drag And Drop Hide Opens a dialog box. Product Lifecycle Sort Product Lifecycle sorting button | Drag And Drop Hide Opens a dialog box. Availability Sort Availability sorting button | Drag And Drop Hide Opens a dialog box. 1ku List Price Sort 1ku List Price sorting button | Drag And Drop Hide Opens a dialog box. Package Sort Package sorting button | Drag And Drop Hide Opens a dialog box. Topology Sort Topology sorting button | Drag And Drop Hide Opens a dialog box. Target Applications Sort Target Applications sorting button | Drag And Drop Hide Opens a dialog box. Interface Sort Interface sorting button | Drag And Drop Hide Opens a dialog box. Resolution Sort Resolution sorting button | Drag And Drop Hide Opens a dialog box. # of Internal Photodiodestyp Sort # of Internal Photodiodes sorting button | Drag And Drop Hide Opens a dialog box. # of External LED Drivers Sort # of External LED Drivers sorting button | Drag And Drop Hide Opens a dialog box. # of External Current Inputs Sort # of External Current Inputs sorting button | Drag And Drop Hide Opens a dialog box. Comments Sort Comments sorting button | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Default Values 6/6 Values Selected | to$ US | Default Values 22/22 Values Selected | Default Values 7/7 Values Selected | Default Values 39/39 Values Selected | Default Values 4/4 Values Selected | Default Values 8/8 Values Selected | Default Values 4/4 Values Selected | Default Values 9/9 Values Selected | Default Values 6/6 Values Selected | |||||
Compact, Dual-Channel, Precision, Programmable Gain Transimpedance Amplifier (PGTIA) | Recommended for New Designs | 21216 | $3.55 (ADA4351-2ACPZ-RL) | 16-Lead LFCSP (3mm x 3mm x 0.75mm) | - | - | - | - | - | - | 2 | Small, Dual-Channel, Precision, Programmable-Gain, Transimpedance Amplifiers (PGTIAs) | ||
High SNR Dual-Channel AFE for Multi-Wavelength Optical Spectroscopy | Recommended for New Designs | 2530 | $3.74 (MAX86180ENB+T) | EVALUATION BOARDS,35-WLCSP-N/A | Optical AFE, Optical Mixed Signal | At-home Monitoring, Finger-based, Infectious Disease detection wearable, PPG, Remote Patient Monitors (RPM), SPO2, Vital Signs, Wearable Devices, Wearable devices for Fitness, Wearable Patient Monitors, Wellness and Medical, Wellness Watches, Wrist-HRM | I2C/SMBus, SPI | 20 | - | 32 | 6 | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | ||
Multimodal Sensor Front End | Recommended for New Designs | 19697 | $3.40 (ADPD4200BCBZR7) | CHIPS W/SOLDER BUMPS/WLCSP | Optical Mixed Signal | Wearable Devices, Wearable Patient Monitors, Wrist-HRM | SPI | 32 | - | - | - | Multimodal Sensor Front End | ||
MAX86177 Add to My Cart Add to My Analog | Quad-Channel AFE for Low-Power Heart Rate Monitor and Pulse Oximeter | Production | 4231 | $4.24 (MAX86177ENI+T) | 28-WLCSP-N/A | Optical AFE | Hearables, Remote Patient Monitors (RPM), Wearable Devices, Wearable devices for Fitness, Wearable Patient Monitors, Wellness and Medical, Wellness Watches, Wrist-worn | - | 20 | - | 6 | 8 | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | |
MAX86173 Add to My Cart Add to My Analog | Dual-Channel Optical AFE with High Signal-to-Noise Ratio for Wearable Health | Recommended for New Designs | 125390 | $3.25 (MAX86173ENI+T) | 28-WLCSP-N/A | Optical AFE | Finger-based, Hearables, Wrist-worn | - | 19 | - | - | 2 | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | |
Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | Production | 107748 | $2.70 (MAX86174AENE+T) | N161B1+1 | Optical AFE | At-home Monitoring, Finger-based, Infectious Disease detection wearable, Wearable Devices, Wrist-worn | - | 20 | - | 4 | 2 | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | ||
Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | Pre-Release | Check Distributor Inventory | - | - | Optical AFE | At-home Monitoring, Finger-based, Infectious Disease detection wearable, Wearable Devices, Wrist-worn | - | 20 | - | 4 | - | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | ||
Ultra-Low-Power, Optical PPG and Single-Lead ECG AFE | Production | 2942 | $3.39 (MAX30005ENX+T) | 36-WLCSP-N/A | Mixed Signal AFE | Arrhythmia Detection Patches, Chest Straps, Covid Detection Patches, Disposable ECG Monitors, ECG AFE, Infectious Disease detection wearable, Wearable Patient Monitors, Wrist-worn | - | 18 | - | - | - | Ultra-Low-Power, Optical PPG and Single-Lead ECG AFE | ||
Ultra-Low-Power, Optical PPG and Single-Lead ECG AFE | Production | 1407 | $5.62 (MAX86176ENX+T) | 36-WLCSP-N/A | Optical Mixed Signal | Arrhythmia Detection Patches, At-home Monitoring, Disposable ECG Monitors, ECG Monitors, Finger-based, Wearable Devices, Wearable Patient Monitors, Wrist-worn | - | 19 | - | - | - | Ultra-Low Power, Optical PPG and Single Lead ECG AFE with Integrated Leads-Off Detection | ||
Programmable Transimpedance, Current to Bits Receiver μModule | Recommended for New Designs | 5763 | $126.40 (ADA4355ABCZ) | 84-Ball CSP-BGA (12mm x 6mm x 1.5mm) | - | - | - | - | - | - | - | Programmable Transimpedance, Current to Bits Receiver μModule | ||
Multimodal Sensor Front End | Recommended for New Designs | 740 | $7.25 (ADPD4100BCBZR7) | 35-Ball WLCSP (2.14 mm x 3.11 mm x 0.50 mm) | Optical Mixed Signal | Angle Sensor, Contact Impedance, ECG, PPG, Proximity, Smoke Detection, SPO2, Vital Signs, Wrist-HRM | SPI | 14 | 0 | 8 | 8 | Multimodal Sensor Front End | ||
Multimodal Sensor Front End | Recommended for New Designs | 87295 | $7.25 (ADPD4101BCBZR7) | 33-Ball WLCSP (2.14 mm x 3.11 mm x 0.50 mm) | Optical Mixed Signal | Angle Sensor, Contact Impedance, ECG, PPG, Proximity, Smoke Detection, SPO2, Vital Signs, Wrist-HRM | I2C/SMBus | 14 | 0 | 8 | 8 | Multimodal Sensor Front End | ||
MAX86170A Add to My Cart Add to My Analog | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | Recommended for New Designs | 1809 | $3.89 (MAX86170AENG+T) | 24-WLCSP-N/A | Optical AFE | Finger-based, Hearables, Wearable Devices, Wearable Patient Monitors, Wrist-worn | - | 19 | - | - | - | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | |
MAX86170B Add to My Cart Add to My Analog | Low-Noise AFE for Pulse Oximeter and Heart Rate Monitor | Production | 33313 | $1.49 (MAX86170BENG+T) | 24-WLCSP-N/A | Optical AFE | At-home Monitoring, Hearables, Wearable Devices, Wearable Patient Monitors, Wrist-worn | - | 19 | - | - | - | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor AFE for Wearable Health | |
Low-Noise AFE for Pulse Oximeter and Heart Rate Monitor | Production | 241 | $4.79 (MAX86171ENI+T) | 28-WLCSP-N/A | Optical AFE | At-home Monitoring, Finger-based, Wearable Devices, Wearable Patient Monitors, Wrist-worn | - | 19 | - | - | - | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor for Wearable Health | ||
Multimodal Sensor Front End | Production | 79784 | $7.25 (ADPD4000BCBZR7) | 35-Ball WLCSP (2.14 mm x 3.11 mm x 0.50 mm) | Optical Mixed Signal | Angle Sensor, Contact Impedance, ECG, PPG, Smoke Detection, SPO2, Vital Signs, Wrist-HRM | SPI | 14 | 0 | 8 | 8 | Multimodal Sensor Front End | ||
Multimodal Sensor Front End | Production | 296 | $7.25 (ADPD4001BCBZR7) | 33-Ball WLCSP (2.14 mm x 3.11 mm x 0.50 mm) | Optical Mixed Signal | Angle Sensor, Contact Impedance, ECG, PPG, Smoke Detection, SPO2, Vital Signs, Wrist-HRM | I2C/SMBus | 14 | 0 | 8 | 8 | Multimodal Sensor Front End | ||
PPG Optical Sensor Module with Integrated Red/IR Emitters and AFE | Not Recommended for New Designs | 8066 | $4.71 (ADPD144RI-ACEZ-RL) | 12-Lead LGA_CAV (2.8mm x 5mm x 1.35mm) | LED Driver, Mixed Signal AFE, Photodiodes | SPO2 | I2C/SMBus | - | 4 | 2 | 0 | PPG Optical Sensor Module with Integrated Red/IR Emitters and AFE | ||
Integrated Photoplethysmogram and Electrocardiogram Bio-Sensor Module For Mobile Health | Last Time Buy | 305 | - | 22-LGA_CAV-3.3x5.6x1.3 | Mixed Signal AFE | ECG Monitors, Finger-based | I2C/SMBus | 19 | 1 | - | - | Integrated Photoplethysmogram and Electrocardiogram Bio-Sensor Module For Mobile Health | ||
Photometric Front Ends | Recommended for New Designs | 18432 | $3.22 (ADPD1081BCBZR7) | 17-Ball WLCSP | Mixed Signal AFE | Contact Impedance, ECG, Gesture, Position, PPG, Proximity, SPO2, Vital Signs, Wrist-HRM | SPI | 14 | 0 | 3 | 2 | Multimodal Sensor Front End | ||
Photometric Front Ends | Recommended for New Designs | 832509 | $3.22 (ADPD1080BCBZR7) | 16-Ball WLCSP (1.4mm x 2.46mm),28-Lead LFCSP (4mm x 4mm w/ EP) | Mixed Signal AFE | Contact Impedance, ECG, Gesture, Position, PPG, Proximity, SPO2, Wrist-HRM | I2C/SMBus | 14 | 0 | 3 | 8 | Multimodal Sensor Front End | ||
Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor for Wearable Health | Production | Check Distributor Inventory | $3.99 (MAX86140ENP+T) | 20-WLCSP-N/A | Optical AFE | At-home Monitoring, Finger-based, Wearable Devices, Wearable Patient Monitors, Wrist-worn | - | 19 | - | 3 | 1 | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor for Wearable Health | ||
Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor for Wearable Health | Production | 9 | $4.39 (MAX86141ENP+T) | 20-WLCSP-N/A | Optical AFE | At-home Monitoring, Finger-based, Hearables, Wearable Devices, Wearable Patient Monitors, Wrist-worn | - | 19 | - | 3 | 2 | Best-in-Class Optical Pulse Oximeter and Heart-Rate Sensor for Wearable Health | ||
Optimized Pulse-Oximeter and Heart Rate AFE for Wearable Health | Production | 7500 | $3.25 (MAX30110EWG+T) | 24-WLCSP-N/A | Optical AFE | At-home Monitoring, Finger-based, Wearable Devices, Wearable Patient Monitors, Wrist-worn | SPI | 19 | - | - | - | Optimized Pulse-Oximeter and Heart Rate AFE for Wearable Health | ||
Optimized Pulse-Oximeter and Heart Rate AFE for Wearable Health | Production | 85000 | $3.25 (MAX30112EWG+T) | 24-WLCSP-N/A | Optical AFE | At-home Monitoring, Finger-based, Wearable Devices, Wearable Patient Monitors, Wrist-worn | I2C/SMBus | 19 | - | - | - | Optimized Pulse-Oximeter and Heart Rate AFE for Wearable Health |